Products / EnergyPack

Foxtheon EnergyPack

Hybrid BESS for On-Site Power

Foxtheon EnergyPack is a range of mobile and containerized hybrid battery energy storage systems (hybrid BESS). It works with compatible diesel generators, grid connections or solar to support temporary, weak-grid and off-grid power.

EnergyPack · P & M Series
Foxtheon EnergyPack P150 battery storage unitP150
Foxtheon EnergyPack M300 Series battery storage unitM300 Series
Foxtheon EnergyPack M600 containerized battery storage unitM600
EnergyPack lineupSelected P and M Series models
Flexible power inputsExisting generator, grid or solar
Peak load supportBattery power for short demand spikes
P Series and M SeriesCompare output, storage and deployment

Model selection

Choose an EnergyPack series

Start with the load profile. Short, high-power bursts and hours of battery operation place different demands on a system.

Temporary and mobile power

Start with P Series

For rental fleets, temporary sites and equipment with short peaks, such as cranes or motor-driven tools.

View P Series models ↓
Off-grid and industrial storage

Start with M Series

For remote facilities, industrial sites and microgrids where battery runtime drives the design.

View M Series models ↓

P Series

Rental, construction and short peak loads

Foxtheon EnergyPack P150

P150

Rental fleets, site compounds and crane support.

Rated power
170 kVA
Peak power
400 kVA · 10 s
Nominal capacity
169.69 kWh
View P150 specifications →
Foxtheon EnergyPack P300

P300

Mid-size construction equipment and temporary projects.

Rated power
377 kVA
Peak power
600 kVA · 10 s
Nominal capacity
377 kWh
View P300 specifications →
Foxtheon EnergyPack P500 / P500+

P500 / P500+

Larger temporary sites and industrial loads.

P500
Rated power
500 kVA
Peak power
750 kVA · 10 s
Nominal capacity
509 kWh
P500+
Rated power
500 kVA
Peak power
750 kVA · 10 s
Nominal capacity
678 kWh
View P500 specifications →

M Series

Remote facilities, microgrids and longer battery runtime

Foxtheon EnergyPack M100

M100

Generator assist and auxiliary loads.

Rated power
100 kVA
Overload power
125 kVA · 60 s
Nominal capacity
188 kWh
View M100 specifications →
Foxtheon EnergyPack M150 / M150 Pro

M150 / M150 Pro

Site offices, camps and off-grid facilities.

M150
Rated power
150 kVA
Peak power
225 kVA · 3 s
Nominal capacity
237 kWh
M150 Pro
Rated power
237 kVA
Peak power
300 kVA · 60 s
Nominal capacity
237 kWh
View M150 specifications →
Foxtheon EnergyPack M300 / M300 Pro

M300 / M300 Pro

Remote sites and industrial microgrids.

M300
Rated power
300 kVA
Peak power
450 kVA · 60 s
Nominal capacity
474 kWh
M300 Pro
Rated power
450 kVA
Peak power
600 kVA · 60 s
Nominal capacity
474 kWh
View M300 specifications →
Foxtheon EnergyPack M600 / M600+

M600 / M600+

Large projects and higher energy demand.

M600
Rated power
675 kVA
Peak power
843 kVA · 60 s
Nominal capacity
711 kWh
M600+
Rated power
675 kVA
Peak power
1,000 kVA · 10 s
Nominal capacity
948.48 kWh
View M600 specifications →

Power ratings apply at the durations shown. Battery figures are nominal capacities. Ask Foxtheon about P600, M900 and other configurations.

System operation

How EnergyPack hybrid BESS works

EnergyPack pairs battery storage with a compatible generator, grid connection or solar installation. FoxMind coordinates charging and discharging. The battery can support short demand peaks and suitable low loads while the external source supports sustained demand.

External powerGenerator, grid or solar
Site power systemEnergyPack charges and discharges as needed
Site loadsSustained demand and short peaks
01

Charge when capacity is available

The battery charges when the source has spare capacity or solar generation exceeds site demand.

02

Support short peaks

When equipment starts or the load rises sharply, the battery can supply additional power within the system's limits.

03

Cover suitable low loads

Where the controls and load allow it, the battery can run smaller loads while the generator is off.

Illustrative load profile

When the battery supplies extra power

PowerTime Crane startup
Blue · site demand and baselineOrange · battery contribution

Applications

Find the right setup for your site

Construction sites

Support cranes and other intermittent loads when the grid connection or generator has limited capacity.

Explore construction power

Rental fleets

Pair battery units with compatible rental generators for mobile power, events and noise-sensitive periods.

Explore rental power

Mining and remote sites

Use battery storage to manage auxiliary loads or integrate with a remote site's microgrid.

Explore remote industrial power

Field case

EnergyPack in Belgium

EnergyPack hybrid power setup for a tracked crawler in Belgium
Trenchless construction

Supporting a crawler with a smaller generator

At a Denys project, the generator supplied baseline power while the EnergyPack supported the crawler's short demand peaks.

35 kVAStage V generator
75 kWSoft-start crawler motor
Read the Belgium case study

Frequently asked questions

EnergyPack sizing and integration

What is the difference between EnergyPack and HybridPack?

EnergyPack adds battery storage to a compatible external power source such as a generator, grid connection or solar installation. HybridPack combines a diesel generator and battery storage in one unit for off-grid power. Explore HybridPack hybrid generators.

Can I use EnergyPack with my existing generator?

EnergyPack can work with compatible generators. Confirm the generator rating, voltage, frequency and controls interface, along with the expected load profile, before selecting a model.

What data do I need to size an EnergyPack?

Provide typical and maximum loads, peak duration and frequency, required battery runtime and details of the available sources. Use a logged load profile when available, since a single peak reading leaves out how long and how often the system must support that load.

Can EnergyPack support a site with a limited grid connection?

In a suitable installation, EnergyPack can charge when spare grid capacity is available and discharge during short periods of higher demand. Sizing depends on the connection limit, the size and duration of the peaks and the time available to recharge.

Project sizing

Size an EnergyPack for your site

Share your existing power source, peak demand and required battery runtime with Foxtheon.

Discuss your site with Foxtheon →

Get A Quote